Показано с 281 по 300 из 17320

2AT0420-6FD42-6KT8 Подробнее   

FLENDER Oil supply system; Pressure and lubrication system Size: OWTE, Size: 6; Cooling medium: Water; Positioning: Tank; Pump type: Single pump, Gearwheel; Oil filter type: Double change over filter; Indication/Monitoring: Package BN; Protection class: IP55; Line voltage: 400 V; Line frequency: 50 Hz; Oil flow rate: 72.0 l/min at 50 Hz;

Datasheet: скачать Pdf Стоимость: по запросу Склад: по запросу

2AT0420-6FD42-8DJ1 Подробнее   

FLENDER Oil supply system; Pressure and lubrication system Size: OWTE, Size: 6; Cooling medium: Water; Positioning: Tank; Pump type: Single pump, Gearwheel; Oil filter type: Double change over filter; Indication/Monitoring: Package BM; Protection class: IP55; Line voltage: 400 V; Line frequency: 50 Hz; Oil flow rate: 72.0 l/min at 50 Hz;

Datasheet: скачать Pdf Стоимость: по запросу Склад: по запросу

2AT0420-6KY03-0YG2 Подробнее   

FLENDER Oil supply system; Pressure and lubrication system Size: OLGD, Size: 7; Cooling medium: Air; Positioning: Base frame, Steel; Pump type: Double pump, Gearwheel; Oil filter type: Double change over filter; Indication/Monitoring: Package AB; Protection class: IP55; Line voltage: 400 V; Line frequency: 50 Hz; Oil flow rate: 105.0 l/min at 50 Hz;

Datasheet: скачать Pdf Стоимость: по запросу Склад: по запросу

2AT0420-6KY03-2RV4 Подробнее   

FLENDER Oil supply system; Pressure and lubrication system Size: OLGD, Size: 7; Cooling medium: Air; Positioning: Base frame, Steel; Pump type: Double pump, Gearwheel; Oil filter type: Double change over filter; Indication/Monitoring: Package AC; Protection class: IP55; Line voltage: 400 V; Line frequency: 50 Hz; Oil flow rate: 105.0 l/min at 50 Hz;

Datasheet: скачать Pdf Стоимость: по запросу Склад: по запросу

2AT0420-6KY57-0LL1 Подробнее   

FLENDER Oil supply system; Pressure and lubrication system Size: OLGE, Size: 7; Cooling medium: Air; Positioning: Base frame, Steel; Pump type: Single pump, Gearwheel; Oil filter type: Double change over filter; Indication/Monitoring: Package AE; Protection class: IP55; Line voltage: 400 V; Line frequency: 50 Hz; Oil flow rate: 105.0 l/min at 50 Hz;

Datasheet: скачать Pdf Стоимость: по запросу Склад: по запросу

2AT0420-6KY57-2EA3 Подробнее   

FLENDER Oil supply system; Pressure and lubrication system Size: OLGE, Size: 7; Cooling medium: Air; Positioning: Base frame, Steel; Pump type: Single pump, Gearwheel; Oil filter type: Double change over filter; Indication/Monitoring: Package AB; Protection class: IP55; Line voltage: 400 V; Line frequency: 50 Hz; Oil flow rate: 105.0 l/min at 50 Hz;

Datasheet: скачать Pdf Стоимость: по запросу Склад: по запросу

2AT0420-6KY61-0YQ6 Подробнее   

FLENDER Oil supply system; Pressure and lubrication system Size: OLGE, Size: 7; Cooling medium: Air; Positioning: Base frame, Steel; Pump type: Single pump, Gearwheel; Oil filter type: Double change over filter; Indication/Monitoring: Package A; Protection class: IP55; Line voltage: 400 V; Line frequency: 50 Hz; Oil flow rate: 105.0 l/min at 50 Hz;

Datasheet: скачать Pdf Стоимость: по запросу Склад: по запросу

2AT0420-6KY71-2PF3 Подробнее   

FLENDER Oil supply system; Pressure and lubrication system Size: OLGE, Size: 7; Cooling medium: Air; Positioning: Base frame, Steel; Pump type: Single pump, Gearwheel; Oil filter type: No filter; Indication/Monitoring: Package AF; Protection class: IP55; Line voltage: 400 V; Line frequency: 50 Hz; Oil flow rate: 105.0 l/min at 50 Hz;

Datasheet: скачать Pdf Стоимость: по запросу Склад: по запросу

2AT0420-6LD77-5VQ3 Подробнее   

FLENDER Oil supply system; Pressure and lubrication system Size: OLTE, Size: 7; Cooling medium: Air; Positioning: Tank; Pump type: Single pump, Gearwheel; Oil filter type: Double change over filter; Indication/Monitoring: Package AJ; Protection class: IP55; Line voltage: 400 V; Line frequency: 50 Hz; Oil flow rate: 105.0 l/min at 50 Hz;

Datasheet: скачать Pdf Стоимость: по запросу Склад: по запросу

2AT0420-6LD77-7PE5 Подробнее   

FLENDER Oil supply system; Pressure and lubrication system Size: OLTE, Size: 7; Cooling medium: Air; Positioning: Tank; Pump type: Single pump, Gearwheel; Oil filter type: Double change over filter; Indication/Monitoring: Package AG; Protection class: IP55; Line voltage: 400 V; Line frequency: 50 Hz; Oil flow rate: 105.0 l/min at 50 Hz;

Datasheet: скачать Pdf Стоимость: по запросу Склад: по запросу

2AT0420-6LD78-0GT7 Подробнее   

FLENDER Oil supply system; Pressure and lubrication system Size: OLTE, Size: 7; Cooling medium: Air; Positioning: Tank; Pump type: Single pump, Gearwheel; Oil filter type: Double change over filter; Indication/Monitoring: Package BJ; Protection class: IP55; Line voltage: 400 V; Line frequency: 50 Hz; Oil flow rate: 105.0 l/min at 50 Hz;

Datasheet: скачать Pdf Стоимость: по запросу Склад: по запросу

2AT0420-6LD78-2AJ0 Подробнее   

FLENDER Oil supply system; Pressure and lubrication system Size: OLTE, Size: 7; Cooling medium: Air; Positioning: Tank; Pump type: Single pump, Gearwheel; Oil filter type: Double change over filter; Indication/Monitoring: Package BB; Protection class: IP55; Line voltage: 400 V; Line frequency: 50 Hz; Oil flow rate: 105.0 l/min at 50 Hz;

Datasheet: скачать Pdf Стоимость: по запросу Склад: по запросу

2AT0420-6MQ63-4BC1 Подробнее   

FLENDER Oil supply system; Pressure and lubrication system Size: OWGD, Size: 7; Cooling medium: Water; Positioning: Base frame, Steel; Pump type: Double pump, Gearwheel; Oil filter type: Double change over filter; Indication/Monitoring: Package AD; Protection class: IP55; Line voltage: 400 V; Line frequency: 50 Hz; Oil flow rate: 105.0 l/min at 50 Hz;

Datasheet: скачать Pdf Стоимость: по запросу Склад: по запросу

2AT0420-6MQ63-5TR3 Подробнее   

FLENDER Oil supply system; Pressure and lubrication system Size: OWGD, Size: 7; Cooling medium: Water; Positioning: Base frame, Steel; Pump type: Double pump, Gearwheel; Oil filter type: Double change over filter; Indication/Monitoring: Package B; Protection class: IP55; Line voltage: 400 V; Line frequency: 50 Hz; Oil flow rate: 105.0 l/min at 50 Hz;

Datasheet: скачать Pdf Стоимость: по запросу Склад: по запросу

2AT0420-6MQ63-7MF5 Подробнее   

FLENDER Oil supply system; Pressure and lubrication system Size: OWGD, Size: 7; Cooling medium: Water; Positioning: Base frame, Steel; Pump type: Double pump, Gearwheel; Oil filter type: Double change over filter; Indication/Monitoring: Package J; Protection class: IP55; Line voltage: 400 V; Line frequency: 50 Hz; Oil flow rate: 105.0 l/min at 50 Hz;

Datasheet: скачать Pdf Стоимость: по запросу Склад: по запросу

2AT0420-6MQ64-0EU7 Подробнее   

FLENDER Oil supply system; Pressure and lubrication system Size: OWGD, Size: 7; Cooling medium: Water; Positioning: Base frame, Steel; Pump type: Double pump, Gearwheel; Oil filter type: Double change over filter; Indication/Monitoring: Package E; Protection class: IP55; Line voltage: 400 V; Line frequency: 50 Hz; Oil flow rate: 105.0 l/min at 50 Hz;

Datasheet: скачать Pdf Стоимость: по запросу Склад: по запросу

2AT0420-6MV47-8XL2 Подробнее   

FLENDER Oil supply system; Pressure and lubrication system Size: OWTD, Size: 7; Cooling medium: Water; Positioning: Tank; Pump type: Double pump, Gearwheel; Oil filter type: Double change over filter; Indication/Monitoring: Package AI; Protection class: IP55; Line voltage: 400 V; Line frequency: 50 Hz; Oil flow rate: 105.0 l/min at 50 Hz;

Datasheet: скачать Pdf Стоимость: по запросу Склад: по запросу

2AT0420-6MV48-1RA4 Подробнее   

FLENDER Oil supply system; Pressure and lubrication system Size: OWTD, Size: 7; Cooling medium: Water; Positioning: Tank; Pump type: Double pump, Gearwheel; Oil filter type: Double change over filter; Indication/Monitoring: Package AK; Protection class: IP55; Line voltage: 400 V; Line frequency: 50 Hz; Oil flow rate: 105.0 l/min at 50 Hz;

Datasheet: скачать Pdf Стоимость: по запросу Склад: по запросу

2AT0420-6MV48-3JP6 Подробнее   

FLENDER Oil supply system; Pressure and lubrication system Size: OWTD, Size: 7; Cooling medium: Water; Positioning: Tank; Pump type: Double pump, Gearwheel; Oil filter type: Double change over filter; Indication/Monitoring: Package AN; Protection class: IP55; Line voltage: 400 V; Line frequency: 50 Hz; Oil flow rate: 105.0 l/min at 50 Hz;

Datasheet: скачать Pdf Стоимость: по запросу Склад: по запросу

2AT0420-6MV48-5CD8 Подробнее   

FLENDER Oil supply system; Pressure and lubrication system Size: OWTD, Size: 7; Cooling medium: Water; Positioning: Tank; Pump type: Double pump, Gearwheel; Oil filter type: Double change over filter; Indication/Monitoring: Package AM; Protection class: IP55; Line voltage: 400 V; Line frequency: 50 Hz; Oil flow rate: 105.0 l/min at 50 Hz;

Datasheet: скачать Pdf Стоимость: по запросу Склад: по запросу