SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEEE C62.11 DCV=33KV, MCOV=27.5KV CLASSIFYING CURRENT 10KA URES (10KA, 8/20) = 98.4KV SINGLE IMP. WITH. RATING 0.6C SWITCHING SURGE ENERGY RATING 4.5KJ/KV ENERGY CLASS B, HEAVY DUTY SHORT-CIRCUIT CURRENT 20KA LEAKAGE DISTANCE 48.4INCH HEIGHT 15.7INCH MDCL 197LBF CARDBOARD PACKAGING
SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR INDOOR USE APPLIED STANDARD: IEEE C62.11 DCV=33KV, MCOV=27.5KV CLASSIFYING CURRENT 10KA URES (10KA, 8/20) = 87.7KV SINGLE IMP. WITH. RATING 0.6C SWITCHING SURGE ENERGY RATING 4.5KJ/KV ENERGY CLASS B, RISER POLE SHORT-CIRCUIT CURRENT 20KA LEAKAGE DISTANCE 18.0INCH HEIGHT 18.5INCH MDCL 167LBF CARDBOARD PACKAGING SHORT TERM LOAD SSL 191LBF MINIMUM ORDER QUANTITY: 12 PCS MIN. QUANTITY SURCHARGE: 200EUR
SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEEE C62.11 DCV=33KV, MCOV=27.5KV CLASSIFYING CURRENT 10KA URES (10KA, 8/20) = 87.7KV SINGLE IMP. WITH. RATING 0.6C SWITCHING SURGE ENERGY RATING 4.5KJ/KV ENERGY CLASS B, RISER POLE SHORT-CIRCUIT CURRENT 20KA LEAKAGE DISTANCE 55.9INCH HEIGHT 18.5INCH MDCL 167LBF CARDBOARD PACKAGING
SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR INDOOR USE APPLIED STANDARD: IEC60099-4 UR=33KV, UC=26.4KV NOMINAL DISCHARGE CURRENT 10KA ARRESTER DESIGNATION: DH URES (10KA, 8/20) = 87.5KV CHARGE TRANSFER RATING 0.4C THERMAL CHARGE TRANSFER RATING 1.1C SHORT-CIRCUIT CURRENT 20KA CREEPAGE DISTANCE 309MM HEIGHT 320MM SHORT TERM LOAD SSL 1560N CARDBOARD PACKAGING
SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEC60099-4 UR=33KV, UC=26.4KV NOMINAL DISCHARGE CURRENT 10KA ARRESTER DESIGNATION: DH URES (10KA, 8/20) = 87.5KV CHARGE TRANSFER RATING 0.4C THERMAL CHARGE TRANSFER RATING 1.1C SHORT-CIRCUIT CURRENT 20KA CREEPAGE DISTANCE 1230MM HEIGHT 400MM SHORT TERM LOAD SSL 1250N CARDBOARD PACKAGING
SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR INDOOR USE APPLIED STANDARD: IEEE C62.11 DCV=36KV, MCOV=29.0KV CLASSIFYING CURRENT 10KA URES (10KA, 8/20) = 108KV SINGLE IMP. WITH. RATING 0.6C SWITCHING SURGE ENERGY RATING 4.5KJ/KV ENERGY CLASS B, HEAVY DUTY SHORT-CIRCUIT CURRENT 20KA LEAKAGE DISTANCE 15.2INCH HEIGHT 15.7INCH MDCL 197LBF CARDBOARD PACKAGING SHORT TERM LOAD SSL 225LBF MINIMUM ORDER QUANTITY: 12 PCS MIN. QUANTITY SURCHARGE: 200EUR
SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEEE C62.11 DCV=36KV, MCOV=29.0KV CLASSIFYING CURRENT 10KA URES (10KA, 8/20) = 108KV SINGLE IMP. WITH. RATING 0.6C SWITCHING SURGE ENERGY RATING 4.5KJ/KV ENERGY CLASS B, HEAVY DUTY SHORT-CIRCUIT CURRENT 20KA LEAKAGE DISTANCE 48.4INCH HEIGHT 15.7INCH MDCL 197LBF CARDBOARD PACKAGING
SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR INDOOR USE APPLIED STANDARD: IEEE C62.11 DCV=36KV, MCOV=29.0KV CLASSIFYING CURRENT 10KA URES (10KA, 8/20) = 95.7KV SINGLE IMP. WITH. RATING 0.6C SWITCHING SURGE ENERGY RATING 4.5KJ/KV ENERGY CLASS B, RISER POLE SHORT-CIRCUIT CURRENT 20KA LEAKAGE DISTANCE 19.5INCH HEIGHT 20.1INCH MDCL 154LBF CARDBOARD PACKAGING SHORT TERM LOAD SSL 176LBF MINIMUM ORDER QUANTITY: 12 PCS MIN. QUANTITY SURCHARGE: 200EUR
SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEEE C62.11 DCV=36KV, MCOV=29.0KV CLASSIFYING CURRENT 10KA URES (10KA, 8/20) = 95.7KV SINGLE IMP. WITH. RATING 0.6C SWITCHING SURGE ENERGY RATING 4.5KJ/KV ENERGY CLASS B, RISER POLE SHORT-CIRCUIT CURRENT 20KA LEAKAGE DISTANCE 62.8INCH HEIGHT 20.1INCH MDCL 154LBF CARDBOARD PACKAGING
SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR INDOOR USE APPLIED STANDARD: IEC60099-4 UR=36KV, UC=28.8KV NOMINAL DISCHARGE CURRENT 10KA ARRESTER DESIGNATION: DH URES (10KA, 8/20) = 95.4KV CHARGE TRANSFER RATING 0.4C THERMAL CHARGE TRANSFER RATING 1.1C SHORT-CIRCUIT CURRENT 20KA CREEPAGE DISTANCE 387MM HEIGHT 400MM SHORT TERM LOAD SSL 1250N CARDBOARD PACKAGING
SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEC60099-4 UR=36KV, UC=28.8KV NOMINAL DISCHARGE CURRENT 10KA ARRESTER DESIGNATION: DH URES (10KA, 8/20) = 95.4KV CHARGE TRANSFER RATING 0.4C THERMAL CHARGE TRANSFER RATING 1.1C SHORT-CIRCUIT CURRENT 20KA CREEPAGE DISTANCE 1230MM HEIGHT 400MM SHORT TERM LOAD SSL 1250N CARDBOARD PACKAGING
SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEC60099-4 UR=39KV, UC=31.2KV NOMINAL DISCHARGE CURRENT 10KA ARRESTER DESIGNATION: DH URES (10KA, 8/20) = 103KV CHARGE TRANSFER RATING 0.4C THERMAL CHARGE TRANSFER RATING 1.1C SHORT-CIRCUIT CURRENT 20KA CREEPAGE DISTANCE 1230MM HEIGHT 400MM SHORT TERM LOAD SSL 1250N CARDBOARD PACKAGING
SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR INDOOR USE APPLIED STANDARD: IEC60099-4 UR=42KV, UC=33.6KV NOMINAL DISCHARGE CURRENT 10KA ARRESTER DESIGNATION: DH URES (10KA, 8/20) = 111KV CHARGE TRANSFER RATING 0.4C THERMAL CHARGE TRANSFER RATING 1.1C SHORT-CIRCUIT CURRENT 20KA CREEPAGE DISTANCE 387MM HEIGHT 400MM SHORT TERM LOAD SSL 1250N CARDBOARD PACKAGING
SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEC60099-4 UR=42KV, UC=33.6KV NOMINAL DISCHARGE CURRENT 10KA ARRESTER DESIGNATION: DH URES (10KA, 8/20) = 111KV CHARGE TRANSFER RATING 0.4C THERMAL CHARGE TRANSFER RATING 1.1C SHORT-CIRCUIT CURRENT 20KA CREEPAGE DISTANCE 1230MM HEIGHT 400MM SHORT TERM LOAD SSL 1250N CARDBOARD PACKAGING
SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR INDOOR USE APPLIED STANDARD: IEC60099-4 UR=45KV, UC=36.0KV NOMINAL DISCHARGE CURRENT 10KA ARRESTER DESIGNATION: DH URES (10KA, 8/20) = 119KV CHARGE TRANSFER RATING 0.4C THERMAL CHARGE TRANSFER RATING 1.1C SHORT-CIRCUIT CURRENT 20KA CREEPAGE DISTANCE 387MM HEIGHT 400MM SHORT TERM LOAD SSL 1250N CARDBOARD PACKAGING
SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEC60099-4 UR=45KV, UC=36.0KV NOMINAL DISCHARGE CURRENT 10KA ARRESTER DESIGNATION: DH URES (10KA, 8/20) = 119KV CHARGE TRANSFER RATING 0.4C THERMAL CHARGE TRANSFER RATING 1.1C SHORT-CIRCUIT CURRENT 20KA CREEPAGE DISTANCE 1230MM HEIGHT 400MM SHORT TERM LOAD SSL 1250N CARDBOARD PACKAGING
SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR INDOOR USE APPLIED STANDARD: IEC60099-4 UR=48KV, UC=38.4KV NOMINAL DISCHARGE CURRENT 10KA ARRESTER DESIGNATION: DH URES (10KA, 8/20) = 127KV CHARGE TRANSFER RATING 0.4C THERMAL CHARGE TRANSFER RATING 1.1C SHORT-CIRCUIT CURRENT 20KA CREEPAGE DISTANCE 387MM HEIGHT 400MM SHORT TERM LOAD SSL 1250N CARDBOARD PACKAGING
SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEC60099-4 UR=48KV, UC=38.4KV NOMINAL DISCHARGE CURRENT 10KA ARRESTER DESIGNATION: DH URES (10KA, 8/20) = 127KV CHARGE TRANSFER RATING 0.4C THERMAL CHARGE TRANSFER RATING 1.1C SHORT-CIRCUIT CURRENT 20KA CREEPAGE DISTANCE 1230MM HEIGHT 400MM SHORT TERM LOAD SSL 1250N CARDBOARD PACKAGING
SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR INDOOR USE APPLIED STANDARD: IEC60099-4 UR=51KV, UC=40.8KV NOMINAL DISCHARGE CURRENT 10KA ARRESTER DESIGNATION: DH URES (10KA, 8/20) = 135KV CHARGE TRANSFER RATING 0.4C THERMAL CHARGE TRANSFER RATING 1.1C SHORT-CIRCUIT CURRENT 20KA CREEPAGE DISTANCE 456MM HEIGHT 470MM SHORT TERM LOAD SSL 1060N CARDBOARD PACKAGING
SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEC60099-4 UR=51KV, UC=40.8KV NOMINAL DISCHARGE CURRENT 10KA ARRESTER DESIGNATION: DH URES (10KA, 8/20) = 135KV CHARGE TRANSFER RATING 0.4C THERMAL CHARGE TRANSFER RATING 1.1C SHORT-CIRCUIT CURRENT 20KA CREEPAGE DISTANCE 1420MM HEIGHT 470MM SHORT TERM LOAD SSL 1060N CARDBOARD PACKAGING