SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR INDOOR USE APPLIED STANDARD: IEC60099-4 UR=6KV, UC=4.8KV NOMINAL DISCHARGE CURRENT 10KA ARRESTER DESIGNATION: DH URES (10KA, 8/20) = 15.9KV CHARGE TRANSFER RATING 0.4C THERMAL CHARGE TRANSFER RATING 1.1C SHORT-CIRCUIT CURRENT 20KA CREEPAGE DISTANCE 162MM HEIGHT 170MM SHORT TERM LOAD SSL 2940N CARDBOARD PACKAGING
SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEC60099-4 UR=6KV, UC=4.8KV NOMINAL DISCHARGE CURRENT 10KA ARRESTER DESIGNATION: DH URES (10KA, 8/20) = 15.9KV CHARGE TRANSFER RATING 0.4C THERMAL CHARGE TRANSFER RATING 1.1C SHORT-CIRCUIT CURRENT 20KA CREEPAGE DISTANCE 372MM HEIGHT 170MM SHORT TERM LOAD SSL 2940N CARDBOARD PACKAGING
SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR INDOOR USE APPLIED STANDARD: IEEE C62.11 DCV=9.0KV, MCOV=7.65KV CLASSIFYING CURRENT 10KA URES (10KA, 8/20) = 28.1KV SINGLE IMP. WITH. RATING 0.6C SWITCHING SURGE ENERGY RATING 4.5KJ/KV ENERGY CLASS B, HEAVY DUTY SHORT-CIRCUIT CURRENT 20KA LEAKAGE DISTANCE 6.4INCH HEIGHT 6.7INCH MDCL 463LBF CARDBOARD PACKAGING
SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEEE C62.11 DCV=9.0KV, MCOV=7.65KV CLASSIFYING CURRENT 10KA URES (10KA, 8/20) = 28.1KV SINGLE IMP. WITH. RATING 0.6C SWITCHING SURGE ENERGY RATING 4.5KJ/KV ENERGY CLASS B, HEAVY DUTY SHORT-CIRCUIT CURRENT 20KA LEAKAGE DISTANCE 14.6INCH HEIGHT 6.7INCH MDCL 463LBF CARDBOARD PACKAGING
SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR INDOOR USE APPLIED STANDARD: IEEE C62.11 DCV=9.0KV, MCOV=7.65KV CLASSIFYING CURRENT 10KA URES (10KA, 8/20) = 23.9KV SINGLE IMP. WITH. RATING 0.6C SWITCHING SURGE ENERGY RATING 4.5KJ/KV ENERGY CLASS B, RISER POLE SHORT-CIRCUIT CURRENT 20KA LEAKAGE DISTANCE 6.4INCH HEIGHT 6.7INCH MDCL 463LBF CARDBOARD PACKAGING SHORT TERM LOAD SSL 528LBF MINIMUM ORDER QUANTITY: 12 PCS MIN. QUANTITY SURCHARGE: 200EUR
SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEEE C62.11 DCV=9.0KV, MCOV=7.65KV CLASSIFYING CURRENT 10KA URES (10KA, 8/20) = 23.9KV SINGLE IMP. WITH. RATING 0.6C SWITCHING SURGE ENERGY RATING 4.5KJ/KV ENERGY CLASS B, RISER POLE SHORT-CIRCUIT CURRENT 20KA LEAKAGE DISTANCE 14.6INCH HEIGHT 6.7INCH MDCL 463LBF CARDBOARD PACKAGING
SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR INDOOR USE APPLIED STANDARD: IEC60099-4 UR=9KV, UC=7.2KV NOMINAL DISCHARGE CURRENT 10KA ARRESTER DESIGNATION: DH URES (10KA, 8/20) = 23.9KV CHARGE TRANSFER RATING 0.4C THERMAL CHARGE TRANSFER RATING 1.1C SHORT-CIRCUIT CURRENT 20KA CREEPAGE DISTANCE 162MM HEIGHT 170MM SHORT TERM LOAD SSL 2940N CARDBOARD PACKAGING
SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEC60099-4 UR=9KV, UC=7.2KV NOMINAL DISCHARGE CURRENT 10KA ARRESTER DESIGNATION: DH URES (10KA, 8/20) = 23.9KV CHARGE TRANSFER RATING 0.4C THERMAL CHARGE TRANSFER RATING 1.1C SHORT-CIRCUIT CURRENT 20KA CREEPAGE DISTANCE 372MM HEIGHT 170MM SHORT TERM LOAD SSL 2940N CARDBOARD PACKAGING
SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR INDOOR USE APPLIED STANDARD: IEEE C62.11 DCV=10KV, MCOV=8.40KV CLASSIFYING CURRENT 10KA URES (10KA, 8/20) = 29.4KV SINGLE IMP. WITH. RATING 0.6C SWITCHING SURGE ENERGY RATING 4.5KJ/KV ENERGY CLASS B, HEAVY DUTY SHORT-CIRCUIT CURRENT 20KA LEAKAGE DISTANCE 6.4INCH HEIGHT 6.7INCH MDCL 463LBF CARDBOARD PACKAGING SHORT TERM LOAD SSL 528LBF MINIMUM ORDER QUANTITY: 12 PCS MIN. QUANTITY SURCHARGE: 200EUR
SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEEE C62.11 DCV=10KV, MCOV=8.40KV CLASSIFYING CURRENT 10KA URES (10KA, 8/20) = 29.4KV SINGLE IMP. WITH. RATING 0.6C SWITCHING SURGE ENERGY RATING 4.5KJ/KV ENERGY CLASS B, HEAVY DUTY SHORT-CIRCUIT CURRENT 20KA LEAKAGE DISTANCE 14.6INCH HEIGHT 6.7INCH MDCL 463LBF CARDBOARD PACKAGING
SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR INDOOR USE APPLIED STANDARD: IEEE C62.11 DCV=10KV, MCOV=8.40KV CLASSIFYING CURRENT 10KA URES (10KA, 8/20) = 26.6KV SINGLE IMP. WITH. RATING 0.6C SWITCHING SURGE ENERGY RATING 4.5KJ/KV ENERGY CLASS B, RISER POLE SHORT-CIRCUIT CURRENT 20KA LEAKAGE DISTANCE 7.5INCH HEIGHT 7.9INCH MDCL 393LBF CARDBOARD PACKAGING SHORT TERM LOAD SSL 448LBF MINIMUM ORDER QUANTITY: 12 PCS MIN. QUANTITY SURCHARGE: 200EUR
SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEEE C62.11 DCV=10KV, MCOV=8.40KV CLASSIFYING CURRENT 10KA URES (10KA, 8/20) = 26.6KV SINGLE IMP. WITH. RATING 0.6C SWITCHING SURGE ENERGY RATING 4.5KJ/KV ENERGY CLASS B, RISER POLE SHORT-CIRCUIT CURRENT 20KA LEAKAGE DISTANCE 19.1INCH HEIGHT 7.9INCH MDCL 393LBF CARDBOARD PACKAGING
SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR INDOOR USE APPLIED STANDARD: IEC60099-4 UR=10.5KV, UC=8.4KV NOMINAL DISCHARGE CURRENT 10KA ARRESTER DESIGNATION: DH URES (10KA, 8/20) = 27.8KV CHARGE TRANSFER RATING 0.4C THERMAL CHARGE TRANSFER RATING 1.1C SHORT-CIRCUIT CURRENT 20KA CREEPAGE DISTANCE 162MM HEIGHT 170MM SHORT TERM LOAD SSL 2940N CARDBOARD PACKAGING
SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEC60099-4 UR=10.5KV, UC=8.4KV NOMINAL DISCHARGE CURRENT 10KA ARRESTER DESIGNATION: DH URES (10KA, 8/20) = 27.8KV CHARGE TRANSFER RATING 0.4C THERMAL CHARGE TRANSFER RATING 1.1C SHORT-CIRCUIT CURRENT 20KA CREEPAGE DISTANCE 372MM HEIGHT 170MM SHORT TERM LOAD SSL 2940N CARDBOARD PACKAGING
SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR INDOOR USE APPLIED STANDARD: IEEE C62.11 DCV=12KV, MCOV=10.2KV CLASSIFYING CURRENT 10KA URES (10KA, 8/20) = 37.3KV SINGLE IMP. WITH. RATING 0.6C SWITCHING SURGE ENERGY RATING 4.5KJ/KV ENERGY CLASS B, HEAVY DUTY SHORT-CIRCUIT CURRENT 20KA LEAKAGE DISTANCE 7.5INCH HEIGHT 7.9INCH MDCL 393LBF CARDBOARD PACKAGING SHORT TERM LOAD SSL 448LBF MINIMUM ORDER QUANTITY: 12 PCS MIN. QUANTITY SURCHARGE: 200EUR
SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEEE C62.11 DCV=12KV, MCOV=10.2KV CLASSIFYING CURRENT 10KA URES (10KA, 8/20) = 37.3KV SINGLE IMP. WITH. RATING 0.6C SWITCHING SURGE ENERGY RATING 4.5KJ/KV ENERGY CLASS B, HEAVY DUTY SHORT-CIRCUIT CURRENT 20KA LEAKAGE DISTANCE 19.1INCH HEIGHT 7.9INCH MDCL 393LBF CARDBOARD PACKAGING
SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR INDOOR USE APPLIED STANDARD: IEEE C62.11 DCV=12KV, MCOV=10.2KV CLASSIFYING CURRENT 10KA URES (10KA, 8/20) = 31.9KV SINGLE IMP. WITH. RATING 0.6C SWITCHING SURGE ENERGY RATING 4.5KJ/KV ENERGY CLASS B, RISER POLE SHORT-CIRCUIT CURRENT 20KA LEAKAGE DISTANCE 9.1INCH HEIGHT 9.4INCH MDCL 328LBF CARDBOARD PACKAGING SHORT TERM LOAD SSL 377LBF MINIMUM ORDER QUANTITY: 12 PCS MIN. QUANTITY SURCHARGE: 200EUR
SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEEE C62.11 DCV=12KV, MCOV=10.2KV CLASSIFYING CURRENT 10KA URES (10KA, 8/20) = 31.9KV SINGLE IMP. WITH. RATING 0.6C SWITCHING SURGE ENERGY RATING 4.5KJ/KV ENERGY CLASS B, RISER POLE SHORT-CIRCUIT CURRENT 20KA LEAKAGE DISTANCE 23.8INCH HEIGHT 9.4INCH MDCL 328LBF CARDBOARD PACKAGING
SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR INDOOR USE APPLIED STANDARD: IEC60099-4 UR=12KV, UC=9.6KV NOMINAL DISCHARGE CURRENT 10KA ARRESTER DESIGNATION: DH URES (10KA, 8/20) = 31.8KV CHARGE TRANSFER RATING 0.4C THERMAL CHARGE TRANSFER RATING 1.1C SHORT-CIRCUIT CURRENT 20KA CREEPAGE DISTANCE 191MM HEIGHT 200MM SHORT TERM LOAD SSL 2500N CARDBOARD PACKAGING
SURGE ARRESTER 3EK7 FOR MEDIUM VOLTAGE SYSTEMS FOR OUTDOOR USE APPLIED STANDARD: IEC60099-4 UR=12KV, UC=9.6KV NOMINAL DISCHARGE CURRENT 10KA ARRESTER DESIGNATION: DH URES (10KA, 8/20) = 31.8KV CHARGE TRANSFER RATING 0.4C THERMAL CHARGE TRANSFER RATING 1.1C SHORT-CIRCUIT CURRENT 20KA CREEPAGE DISTANCE 485MM HEIGHT 200MM SHORT TERM LOAD SSL 2500N CARDBOARD PACKAGING